Features & Benefits
- no reagents or control consumables are required anymore.
- The new, easy to use interface enables you to program almost all the protocols of microELISA assays currently available on the market.
- PSID – true Positive Sample Identification.
- Accommodating fully barcoded reagents inventory.
- Flexible loading dock for accommodating:
- different slides for loading different vials/bottles of controls/standard/reagents.
- different slides for loading different formats of sample tubes.
- ‘genuine open system’
- Maximised precision and efficient pipetting by using 200 uL tips and 1000 uL tips.
- Zero carry-over by using disposable tips for sample pipetting.
- Detection for clotting, bubbles and insufficient volume during pipetting.
- Level sensing on all instrument liquids and –buffers loaded on the instrument.
- 2-independent pipetting systems ensure maximum efficiency in pipetting speed and distribution of the liquids/samples.
- Each of the two microplates is fully independent programmable for pipetting, temperature, incubation, washing and reading.
- Open system for accommodating maximum flexibility for varying testing needs.
- Personal LAB is using bar coded reagents to ensure maximum control during assay execution and a validated test routine from the assay.
- All bottles (Reagents – Standards – Controls) are accommodated in dedicated and multi-functional sliding trays.
- Multiple reagents/standard sliding trays can be loaded on the work area.
- Reagents bottles up to 60-mL can be loaded on a reagent sliding tray.
- The reagents system is designed for combining more than one assay per reagent tray for maximum flexibility in your daily test routine.
Sample Station
Tubes : Up to 96 positions for tubes 12-13.5 mm diameter, 55-75 mm height
Loading capacity : 96 samples
Sample : identification Positive Sample Identification (PSID) by built-in bar code reader and dedicated sample loading facility
Sample : loading Sample strip loading with bar code reading
Incubation Station
Incubation area : Manages 2 microplates (with independent temperature control)
Temperature : At least 5°C higher than the room temperature or 30°C ÷ 45°C
Stability : ± 1°C
Warm-up : 15 minutes
Pipetting Station
Tip size : 200 or 1000 μL
Sample pipetting : volume 10-200 μL
Reagent pipetting volume : 10-1000 μL
Working area : Manages 2 microplates independently
Syringe dilutors : Two dilutors with 1 mLand 5 mL precision micro-pumps
Syringe 1 mL resolution : 4000 steps on max. stroke
Syringes 5 mL resolution : 2000 steps on max. stroke
Precision for serum samples :
- <5% with 10μL (CV)
- <3.5% with 25μL (CV)
- <2.0% with 50μL (CV)
- <2.0% with 100μL (CV)
Precision for reagents :
- <3.5% with 50μL (CV)
- <2.5% with 100μL (CV)
- <2.5% with 200μL (CV)
Serum dispensing time : <15 min. for 88 samples (volume 100μL)
Reagent dispensing time : <3 min. for 96 wells (volume 100μL)
Washing Station
Washing volumes : 100 to 2000 μL
Wash cycles : 1 to 9
Soak time : 1 second to 3 minutes
Pressure : Low or normal
Instrumentation Dimensions
Size : Width 76 cm, Depth 76 cm, Height 69 cm
Weight : ±75 kg