adaltis
Personal Lab Fully Automated 2 Microplate Analyser

Features & Benefits

- no reagents or control consumables are required anymore.

- The new, easy to use interface enables you to program almost all the protocols of microELISA assays currently available on the market.

- PSID – true Positive Sample Identification.

- Accommodating fully barcoded reagents inventory.

- Flexible loading dock for accommodating:

- different slides for loading different vials/bottles of controls/standard/reagents.

  • different slides for loading different formats of sample tubes.
  • ‘genuine open system’

- Maximised precision and efficient pipetting by using 200 uL tips and 1000 uL tips.

- Zero carry-over by using disposable tips for sample pipetting.

- Detection for clotting, bubbles and insufficient volume during pipetting.

- Level sensing on all instrument liquids and –buffers loaded on the instrument.

- 2-independent pipetting systems ensure maximum efficiency in pipetting speed and distribution of the liquids/samples.

- Each of the two microplates is fully independent programmable for pipetting, temperature, incubation, washing and reading.

- Open system for accommodating maximum flexibility for varying testing needs.

- Personal LAB is using bar coded reagents to ensure maximum control during assay execution and a validated test routine from the assay.

- All bottles (Reagents – Standards – Controls) are accommodated in dedicated and multi-functional sliding trays.

- Multiple reagents/standard sliding trays can be loaded on the work area.

- Reagents bottles up to 60-mL can be loaded on a reagent sliding tray.

- The reagents system is designed for combining more than one assay per reagent tray for maximum flexibility in your daily test routine.

 

Sample Station 

   
Tubes  :   Up to 96 positions for tubes 12-13.5 mm diameter, 55-75 mm height
Loading capacity  :   96 samples
Sample  :   identification Positive Sample Identification (PSID) by built-in bar code reader and dedicated sample loading facility
Sample  :   loading Sample strip loading with bar code reading

 

Incubation Station    


Incubation area :  Manages 2 microplates (with independent temperature control)
Temperature :   At least 5°C higher than the room temperature or 30°C ÷ 45°C
Stability  :   ± 1°C
Warm-up  :  15 minutes

Pipetting Station    


Tip size   :  200 or 1000 μL
Sample pipetting  :   volume 10-200 μL
Reagent pipetting volume   :  10-1000 μL
Working area  :   Manages 2 microplates independently
Syringe dilutors  :   Two dilutors with 1 mLand 5 mL precision micro-pumps
Syringe 1 mL resolution  :   4000 steps on max. stroke
Syringes 5 mL resolution   :  2000 steps on max. stroke
Precision for serum samples   :

  • <5% with 10μL (CV)
  • <3.5% with 25μL (CV)
  • <2.0% with 50μL (CV)
  • <2.0% with 100μL (CV)

Precision for reagents  :

  • <3.5% with 50μL (CV)
  • <2.5% with 100μL (CV)
  • <2.5% with 200μL (CV)

Serum dispensing time :   <15 min. for 88 samples (volume 100μL)
Reagent dispensing time  :  <3 min. for 96 wells (volume 100μL)

 

Washing Station    


Washing volumes  :   100 to 2000 μL
Wash cycles  :   1 to 9
Soak time  :   1 second to 3 minutes
Pressure  :   Low or normal

 

Instrumentation Dimensions    


Size  :   Width 76 cm, Depth 76 cm, Height 69 cm
Weight :  ±75 kg